Transformer Oil Test Kit Manufacturers in Australia, Top Quality Transformer Oil Test Kits Suppliers, Exporters & Service Providers in Australia

We are the leading transformer oil test kit manufacturers in Australia suppliers and exporters & Service Providers offering the new and high quality of transformer oil test kit. This is usually used to test the dielectric strength (or BDV) of the transformer insulation oil. The insulating oil provides the insulation under high voltage potentials. It comes with a built-in LCD, thermal printer, PC interface, memory, real time clock, magnetic stirrer and even supports remote controlled operation. It can easily identify the essential electrical characteristics of transformer oil and used in dielectric strength testing, moisture content analysis and power factor testing.

New Technological updates in our Transformer Oil Test Kit

Our new featured transformer oil test kit is manufactured with multiple types of advanced technological features such as:

  • Advanced Dielectric Breakdown Voltage (BDV) Testers: These new types of transformer oil test kit are fully integrated with digital types of displays and programmable test sequences. The use of motorized stirring mechanisms and auto-calibration enhance precision and repeatability.
  • Compliance with Updated International Standards: Our new transformer oil test kits comply with updated IEC 60156, ASTM D1816, and ARE 6792 standards and new types of modern kits come pre-programmed with multiple test standards, ensuring global compliance.
  • Portable and On-Site Testing Solutions: It comes with new design such as compact, lightweight and battery operated test kit for allowing on the spot testing. We have used new Moisture Content Analyzers and Dissolved Gas Analysis (DGA) kits technology for reducing any kind of downtime.

Technical Specifications

For more clarifications, we have mentioned below a technical sheet of our Transformer Oil Test Kit:

Parameter Specification
Testing Capabilities Dielectric Breakdown Voltage (BDV), Dissolved Gas Analysis (DGA), Moisture Content, Interfacial Tension, Acidity, Resistivity, Flash Point
Voltage Range 0 – 100 kV (Adjustable)
Breakdown Voltage Accuracy ±1% of Full Scale
Voltage Increase Rate 0.5 kV/s, 2 kV/s, 3 kV/s (Selectable)
Electrode Gap Setting Adjustable (1.0 mm – 2.5 mm)
DGA Detection H₂, CH₄, C₂H₂, C₂H₄, C₂H₆, CO, CO₂
Moisture Content (PPM Meter) 1 – 1000 ppm (Karl Fischer Titration)
Interfacial Tension Measurement 0.1 – 50 mN/m
Acidity Test Range 0.001 – 1 mgKOH/g
Resistivity Measurement 10⁶ – 10¹⁴ Ω·m
Flash Point Detection 50 – 300°C
Temperature Range -10°C to 100°C
Temperature Accuracy ± 0.5°C
Test Chamber Type Fully Enclosed, Automatic Electrode Stirring

Features of our Transformer Oil Test Kit

Being the best transformer oil test kit manufacturers and suppliers in Australia, these all types of kits are installed with multiple types of features such as:

  • Dielectric Breakdown Voltage (BDV) Testing: Measures the oil’s insulating strength by determining the voltage at which it breaks down.
  • Dissolved Gas Analysis (DGA): Detects gases like hydrogen, methane, and ethylene to identify early signs of transformer faults.
  • Moisture Content Measurement: Uses Karl Fischer titration or online sensors to detect water contamination in oil.
  • Interfacial Tension (IFT) Testing: Evaluates the aging and contamination of transformer oil by measuring its surface tension.
  • Acidity Testing: Determines the oil’s acidity level, which affects its insulating properties and corrosion potential.
  • Resistivity Measurement: Assesses the oil’s electrical resistance to identify contamination and degradation.
  • Flash Point Testing: Measures the temperature at which transformer oil vapors ignite, ensuring safety standards.
  • Cloud-Based Data Storage & Connectivity: Enables remote monitoring, data logging, and real-time diagnostics using IoT integration.

Applications of our Transformer Oil Test Kit

Being the former transformer oil test kit suppliers, providersin Australia, our transformer oil test kit are highly used in multiple types of industrial sectors such as:

  • Dielectric Strength Testing:
    • Measures the breakdown voltage of transformer oil to determine its insulating capacity.
    • Helps in identifying moisture, dirt, or other contaminants that reduce insulation properties.
  • Moisture Content Analysis:
    • Detects water contamination, which can lead to insulation failure and reduced dielectric strength.
    • Ensures transformer oil maintains its optimal insulating properties.
  • Dissolved Gas Analysis (DGA):
    • Identifies gases produced due to insulation degradation or overheating.
    • Helps in diagnosing faults such as overheating, arcing, or corona discharge.
  • Acidity Testing:
    • Determines the acid content in transformer oil, which affects its longevity and performance.
    • Prevents corrosion of transformer components.
  • Interfacial Tension (IFT) Testing:
    • Measures the ability of oil to resist contamination by water and other impurities.
    • A declining IFT value indicates oil degradation.

Being the best Transformer Oil Test Kit manufacturers, suppliers and exportersin Australia, we as Transpower Switchgear Industries are providing the new transformer oil test kit. These are used in multiple types of applications and industrial sectors for improving overall performance. The use of new and advanced level of technologies helps for getting accurate output. Contact us today for more information!